		<item>
			<title><![CDATA[Microphone water leak please help!]]></title>
			<link>http://www.wanderlodgegurus.com/showthread.php?tid=11681</link>
			<pubDate>Fri, 03 May 2024 15:31:57 +0000</pubDate>
			<guid isPermaLink="false">http://www.wanderlodgegurus.com/showthread.php?tid=11681</guid>
			<description><![CDATA[Hello, I recently bought a 1998 lxi 43! I'm loving it so far but the toilet has started leaking heavily from the air/water valve inside the toilet! It looks like the right cap on it is the culprit. Is there a gasket that should be under the cap? If so does anyone know where to purchase it? <br />
<br />
Thank you very much!<br /><!-- start: postbit_attachments_attachment -->
<br /><img src="images/attachtypes/image.gif" border="0" alt=".jpg" />&nbsp;&nbsp;<a href="attachment.php?aid=2252" target="_blank">17147502474914683017853454715170.jpg</a> (Size: 1.99 MB / Downloads: 626)
<!-- end: postbit_attachments_attachment -->]]></description>
			<content:encoded><![CDATA[Hello, I recently bought a 1998 lxi 43! I'm loving it so far but the toilet has started leaking heavily from the air/water valve inside the toilet! It looks like the right cap on it is the culprit. Is there a gasket that should be under the cap? If so does anyone know where to purchase it? <br />
<br />
Thank you very much!<br /><!-- start: postbit_attachments_attachment -->
<br /><img src="images/attachtypes/image.gif" border="0" alt=".jpg" />&nbsp;&nbsp;<a href="attachment.php?aid=2252" target="_blank">17147502474914683017853454715170.jpg</a> (Size: 1.99 MB / Downloads: 626)
<!-- end: postbit_attachments_attachment -->]]></content:encoded>
		</item>
		<item>
			<title><![CDATA[Shower maker]]></title>
			<link>http://www.wanderlodgegurus.com/showthread.php?tid=11365</link>
			<pubDate>Wed, 04 Sep 2019 21:22:49 +0000</pubDate>
			<guid isPermaLink="false">http://www.wanderlodgegurus.com/showthread.php?tid=11365</guid>
			<description><![CDATA[Does anybody know who the original supplier of the shower base and walls was?  I'd like to do a little work on mine and would like to see if matching stuff is available or whether I need to swap it all out.]]></description>
			<content:encoded><![CDATA[Does anybody know who the original supplier of the shower base and walls was?  I'd like to do a little work on mine and would like to see if matching stuff is available or whether I need to swap it all out.]]></content:encoded>
		</item>
		<item>
			<title><![CDATA[Insinkerator instant hot water]]></title>
			<link>http://www.wanderlodgegurus.com/showthread.php?tid=11329</link>
			<pubDate>Mon, 19 Nov 2018 00:00:36 +0000</pubDate>
			<guid isPermaLink="false">http://www.wanderlodgegurus.com/showthread.php?tid=11329</guid>
			<description><![CDATA[The instant hot water on the kitchen sink hasn’t worked since I bought this bus. Over the weekend the Grohe quick connect water connector on the kitchen faucet finally arrived after it broke off on my last trip. &#36;30+ for a little piece of plastic that took Home Depot three weeks to deliver!  Anyway, while I was under the sink fixing that, I decided to check out the instant hot before just buying a new one. Popped the front cover and checked for voltage. All good there. Then I noticed a fusible link. Hate those things!  Put the meter on it and found it open.  Grabbed a short very light weight jumper and connected around it.  Sure enough, it started heating.  Let it go full cycle and found the temp was way too high so adjusted that down to about 170.  Flushed it out and recycled it and enjoyed a cup of hot chocolate.  Quick google search found a proper Insinkerator brand replacement fusible link on eBay. Grabbed that and will finalize the repair when it arrives. Gotta love the easy (and cheap) fixes!  Maybe this will help someone else not to replace an inoperable instant hot water heater. <br />
<br />
FWIW,]]></description>
			<content:encoded><![CDATA[The instant hot water on the kitchen sink hasn’t worked since I bought this bus. Over the weekend the Grohe quick connect water connector on the kitchen faucet finally arrived after it broke off on my last trip. &#36;30+ for a little piece of plastic that took Home Depot three weeks to deliver!  Anyway, while I was under the sink fixing that, I decided to check out the instant hot before just buying a new one. Popped the front cover and checked for voltage. All good there. Then I noticed a fusible link. Hate those things!  Put the meter on it and found it open.  Grabbed a short very light weight jumper and connected around it.  Sure enough, it started heating.  Let it go full cycle and found the temp was way too high so adjusted that down to about 170.  Flushed it out and recycled it and enjoyed a cup of hot chocolate.  Quick google search found a proper Insinkerator brand replacement fusible link on eBay. Grabbed that and will finalize the repair when it arrives. Gotta love the easy (and cheap) fixes!  Maybe this will help someone else not to replace an inoperable instant hot water heater. <br />
<br />
FWIW,]]></content:encoded>
		</item>
		<item>
			<title><![CDATA[Sewer Connections]]></title>
			<link>http://www.wanderlodgegurus.com/showthread.php?tid=11241</link>
			<pubDate>Mon, 04 Dec 2017 15:47:21 +0000</pubDate>
			<guid isPermaLink="false">http://www.wanderlodgegurus.com/showthread.php?tid=11241</guid>
			<description><![CDATA[Needless to say emptying the tanks is probably the worst part of having a motorhome.<br />
Has any one come up with a simpler / cleaner system?<br />
What about these pumps that use a water hose?<br />
Any suggestions would be appreciated.<br />
<br />
Urnie]]></description>
			<content:encoded><![CDATA[Needless to say emptying the tanks is probably the worst part of having a motorhome.<br />
Has any one come up with a simpler / cleaner system?<br />
What about these pumps that use a water hose?<br />
Any suggestions would be appreciated.<br />
<br />
Urnie]]></content:encoded>
		</item>
		<item>
			<title><![CDATA[Converting Black Tank into a Grey Tank Overflow?]]></title>
			<link>http://www.wanderlodgegurus.com/showthread.php?tid=10853</link>
			<pubDate>Wed, 31 Aug 2016 23:06:10 +0000</pubDate>
			<guid isPermaLink="false">http://www.wanderlodgegurus.com/showthread.php?tid=10853</guid>
			<description><![CDATA[I was just wondering (if anyone would like to humor me)....<br />
If I removed the toilet (in any Wanderlodge) and replaced it with a <br />
"composting toilet" (like....<a href="https://www.youtube.com/watch?v=_E2xOoNov9s" target="_blank">https://www.youtube.com/watch?v=_E2xOoNov9s</a> ),<br />
  <br />
could the abandoned Black Tank then be used as a Grey Tank (overflow)<br />
for longer periods (of dry camping) before dumping?????<br />
<br />
In theory<span style="text-decoration: underline;"> it seems like it could be done....</span><br />
<span style="font-weight: bold;">BUT, Can it be done?</span><br />
<br />
What is your experience?   <br />
Do you think this could be done?]]></description>
			<content:encoded><![CDATA[I was just wondering (if anyone would like to humor me)....<br />
If I removed the toilet (in any Wanderlodge) and replaced it with a <br />
"composting toilet" (like....<a href="https://www.youtube.com/watch?v=_E2xOoNov9s" target="_blank">https://www.youtube.com/watch?v=_E2xOoNov9s</a> ),<br />
  <br />
could the abandoned Black Tank then be used as a Grey Tank (overflow)<br />
for longer periods (of dry camping) before dumping?????<br />
<br />
In theory<span style="text-decoration: underline;"> it seems like it could be done....</span><br />
<span style="font-weight: bold;">BUT, Can it be done?</span><br />
<br />
What is your experience?   <br />
Do you think this could be done?]]></content:encoded>
		</item>
		<item>
			<title><![CDATA[Hooking up to commercial water]]></title>
			<link>http://www.wanderlodgegurus.com/showthread.php?tid=10733</link>
			<pubDate>Thu, 12 May 2016 22:51:44 +0000</pubDate>
			<guid isPermaLink="false">http://www.wanderlodgegurus.com/showthread.php?tid=10733</guid>
			<description><![CDATA[I wasn't able to find a definitive answer to this question so hopefully this isn't a repeat.  We are on our second trip in our 79 FC (the first trip went great after learning the systems).  However, this trip we are having issues with the water hookup.  We followed the instructions left by the previous owner and filled both water tanks but when we turn on the water pump to use the water we just keep having water leak out of the bottom.  The gray tank has been drained and all the valves are turned on so I am not sure what step we are missing.  I should add that we also have the commercial line off.  Literally two days ago we were doing the steps the same exact way in NC and had no issues.  I am sure it is user error but any and all help would be greatly appreciated!  Plus I don't want to have to be the one to tell my girlfriend we are taking campground showers.]]></description>
			<content:encoded><![CDATA[I wasn't able to find a definitive answer to this question so hopefully this isn't a repeat.  We are on our second trip in our 79 FC (the first trip went great after learning the systems).  However, this trip we are having issues with the water hookup.  We followed the instructions left by the previous owner and filled both water tanks but when we turn on the water pump to use the water we just keep having water leak out of the bottom.  The gray tank has been drained and all the valves are turned on so I am not sure what step we are missing.  I should add that we also have the commercial line off.  Literally two days ago we were doing the steps the same exact way in NC and had no issues.  I am sure it is user error but any and all help would be greatly appreciated!  Plus I don't want to have to be the one to tell my girlfriend we are taking campground showers.]]></content:encoded>
		</item>
		<item>
			<title><![CDATA[Air Microphor Down the Road Odor]]></title>
			<link>http://www.wanderlodgegurus.com/showthread.php?tid=10618</link>
			<pubDate>Fri, 13 Nov 2015 16:35:10 +0000</pubDate>
			<guid isPermaLink="false">http://www.wanderlodgegurus.com/showthread.php?tid=10618</guid>
			<description><![CDATA[It seems a common problem with the Microphor air toilet is odor in the back of the bus when going down the road, unless you have dumped prior to departure.  Theories abound about differential pressure, leaking flaps, venturis, etc., etc.<br />
<br />
Having this problem I looked hard when replacing the floor and discovered the problem in at least our bus.  On the back of the toilet hopper there are two valves, one the air inlet valve with a poppet, and one pressure/vacuum release valve. (Bingo!)  I slipped plastic tubing over both and hose clamped them, and then ran them through a hole in the floor inside the conduit box down to the water/dump bay.  Actually I teed them but separate lines work if you have room.<br />
<br />
Many trips with half full black tank have proven this was the cause; no more odor when going down the road.  It took two years of nasty odor to find this.  Hope it helps y'all who have these toilets.<br />
<br />
Attached are two pictures, one before, and one after adding the tubing.<br /><!-- start: postbit_attachments_attachment -->
<br /><img src="images/attachtypes/image.gif" border="0" alt=".jpg" />&nbsp;&nbsp;<a href="attachment.php?aid=1895" target="_blank">Original.JPG</a> (Size: 586.93 KB / Downloads: 1023)
<!-- end: postbit_attachments_attachment --><br /><!-- start: postbit_attachments_attachment -->
<br /><img src="images/attachtypes/image.gif" border="0" alt=".jpg" />&nbsp;&nbsp;<a href="attachment.php?aid=1896" target="_blank">Both Vents Captured..JPG</a> (Size: 587.75 KB / Downloads: 1051)
<!-- end: postbit_attachments_attachment -->]]></description>
			<content:encoded><![CDATA[It seems a common problem with the Microphor air toilet is odor in the back of the bus when going down the road, unless you have dumped prior to departure.  Theories abound about differential pressure, leaking flaps, venturis, etc., etc.<br />
<br />
Having this problem I looked hard when replacing the floor and discovered the problem in at least our bus.  On the back of the toilet hopper there are two valves, one the air inlet valve with a poppet, and one pressure/vacuum release valve. (Bingo!)  I slipped plastic tubing over both and hose clamped them, and then ran them through a hole in the floor inside the conduit box down to the water/dump bay.  Actually I teed them but separate lines work if you have room.<br />
<br />
Many trips with half full black tank have proven this was the cause; no more odor when going down the road.  It took two years of nasty odor to find this.  Hope it helps y'all who have these toilets.<br />
<br />
Attached are two pictures, one before, and one after adding the tubing.<br /><!-- start: postbit_attachments_attachment -->
<br /><img src="images/attachtypes/image.gif" border="0" alt=".jpg" />&nbsp;&nbsp;<a href="attachment.php?aid=1895" target="_blank">Original.JPG</a> (Size: 586.93 KB / Downloads: 1023)
<!-- end: postbit_attachments_attachment --><br /><!-- start: postbit_attachments_attachment -->
<br /><img src="images/attachtypes/image.gif" border="0" alt=".jpg" />&nbsp;&nbsp;<a href="attachment.php?aid=1896" target="_blank">Both Vents Captured..JPG</a> (Size: 587.75 KB / Downloads: 1051)
<!-- end: postbit_attachments_attachment -->]]></content:encoded>
		</item>
		<item>
			<title><![CDATA[Flooded SOB]]></title>
			<link>http://www.wanderlodgegurus.com/showthread.php?tid=10458</link>
			<pubDate>Sat, 25 Apr 2015 15:41:33 +0000</pubDate>
			<guid isPermaLink="false">http://www.wanderlodgegurus.com/showthread.php?tid=10458</guid>
			<description><![CDATA[<a href="http://www.irv2.com/forums/f103/expert-advice-requested-new-2015-king-aire-flooded-with-50-gallons-of-water-243012.html" target="_blank">This thread</a> has been making the rounds on the forums. The owner took delivery of his brand new 2015 Newmar King Aire only to have a water connection fail 3 days after delivery. The connection under his kitchen sink unleashed gushing 50 gallons of water into his RV. <br />
<br />
There are differing points of view represented in the long thread, but most expect Newmar to eventually step up and replace the coach. <br />
<br />
For my entire RV history I've always relied only on my water pump for domestic water delivery. When at a CG I fill up my tank and disconnect from shore relying on my water pump. When leaving the coach I always turn off the pump and I always make certain it's off before retiring. This unfortunate event happened while driving down the road. With a wife and three kids running around we almost always have the water pump on when traveling; I'm hoping that one of my little rascals will spot trouble in this case!]]></description>
			<content:encoded><![CDATA[<a href="http://www.irv2.com/forums/f103/expert-advice-requested-new-2015-king-aire-flooded-with-50-gallons-of-water-243012.html" target="_blank">This thread</a> has been making the rounds on the forums. The owner took delivery of his brand new 2015 Newmar King Aire only to have a water connection fail 3 days after delivery. The connection under his kitchen sink unleashed gushing 50 gallons of water into his RV. <br />
<br />
There are differing points of view represented in the long thread, but most expect Newmar to eventually step up and replace the coach. <br />
<br />
For my entire RV history I've always relied only on my water pump for domestic water delivery. When at a CG I fill up my tank and disconnect from shore relying on my water pump. When leaving the coach I always turn off the pump and I always make certain it's off before retiring. This unfortunate event happened while driving down the road. With a wife and three kids running around we almost always have the water pump on when traveling; I'm hoping that one of my little rascals will spot trouble in this case!]]></content:encoded>
		</item>
		<item>
			<title><![CDATA[Tank supports]]></title>
			<link>http://www.wanderlodgegurus.com/showthread.php?tid=10434</link>
			<pubDate>Wed, 11 Mar 2015 02:07:57 +0000</pubDate>
			<guid isPermaLink="false">http://www.wanderlodgegurus.com/showthread.php?tid=10434</guid>
			<description><![CDATA[Those of you who've had to replace the tank supports, what did you end up using?  While Id like to come up with a large polypropelene (or something similar) sheet to make it out of, I don't think I can do that with any kind of time line required.<br />
<br />
My fresh tank has been seeping for a long time and after removal, I find the bung was never fully sealed to the tank, so it's been seeping from day 1!]]></description>
			<content:encoded><![CDATA[Those of you who've had to replace the tank supports, what did you end up using?  While Id like to come up with a large polypropelene (or something similar) sheet to make it out of, I don't think I can do that with any kind of time line required.<br />
<br />
My fresh tank has been seeping for a long time and after removal, I find the bung was never fully sealed to the tank, so it's been seeping from day 1!]]></content:encoded>
		</item>
		<item>
			<title><![CDATA[plumbing]]></title>
			<link>http://www.wanderlodgegurus.com/showthread.php?tid=10394</link>
			<pubDate>Wed, 31 Dec 2014 19:07:41 +0000</pubDate>
			<guid isPermaLink="false">http://www.wanderlodgegurus.com/showthread.php?tid=10394</guid>
			<description><![CDATA[!st time using this forum.<br />
<br />
Issue with water in our 1989 Wanderlodge.  Have had to replace the water heater and pump, couple months ago. Now seems we have an issue getting the hot water to flow. Cold water is not an issue, pump seems to run fine but we do hear a hammer noise every so often.<br />
<br />
Any ideas, or are there some schematics for the under the bed water system out there? Water Heater does seem to put out hot water. the outlet <br />
pipe is hot. Also kitchen faucet has more pressure then the bathroom.<br />
Thanks]]></description>
			<content:encoded><![CDATA[!st time using this forum.<br />
<br />
Issue with water in our 1989 Wanderlodge.  Have had to replace the water heater and pump, couple months ago. Now seems we have an issue getting the hot water to flow. Cold water is not an issue, pump seems to run fine but we do hear a hammer noise every so often.<br />
<br />
Any ideas, or are there some schematics for the under the bed water system out there? Water Heater does seem to put out hot water. the outlet <br />
pipe is hot. Also kitchen faucet has more pressure then the bathroom.<br />
Thanks]]></content:encoded>
		</item>
		<item>
			<title><![CDATA[Kitchen Faucet Plumbing Questions]]></title>
			<link>http://www.wanderlodgegurus.com/showthread.php?tid=10208</link>
			<pubDate>Sat, 10 May 2014 23:03:19 +0000</pubDate>
			<guid isPermaLink="false">http://www.wanderlodgegurus.com/showthread.php?tid=10208</guid>
			<description><![CDATA[Wanting to change out the kitchen faucet, and before I get started, leads to questions...what have others done regarding the copper/brass pipe/connections that BB installed? Photo attached of the water pipes and fittings.<br /><!-- start: postbit_attachments_attachment -->
<br /><img src="images/attachtypes/image.gif" border="0" alt=".jpg" />&nbsp;&nbsp;<a href="attachment.php?aid=1263" target="_blank">Kitchen Faucet Plumbing.jpg</a> (Size: 2.99 MB / Downloads: 1023)
<!-- end: postbit_attachments_attachment -->]]></description>
			<content:encoded><![CDATA[Wanting to change out the kitchen faucet, and before I get started, leads to questions...what have others done regarding the copper/brass pipe/connections that BB installed? Photo attached of the water pipes and fittings.<br /><!-- start: postbit_attachments_attachment -->
<br /><img src="images/attachtypes/image.gif" border="0" alt=".jpg" />&nbsp;&nbsp;<a href="attachment.php?aid=1263" target="_blank">Kitchen Faucet Plumbing.jpg</a> (Size: 2.99 MB / Downloads: 1023)
<!-- end: postbit_attachments_attachment -->]]></content:encoded>
		</item>
		<item>
			<title><![CDATA[Soft Water for your 'Bird]]></title>
			<link>http://www.wanderlodgegurus.com/showthread.php?tid=10165</link>
			<pubDate>Sat, 15 Mar 2014 05:26:47 +0000</pubDate>
			<guid isPermaLink="false">http://www.wanderlodgegurus.com/showthread.php?tid=10165</guid>
			<description><![CDATA[If this system lives up to its great reviews; it would be ideal to install and use in our coaches. Filter lasts 6 months (maybe longer in a bus?)and costs &#36;50. Anyone have experience with this product?<br />
<br />
<a href="http://www.nuvoh2o.com/nuvo-systems/nuvo-studio-system.html\" target="_blank">http://www.nuvoh2o.com/nuvo-systems/nuvo...stem.html\</a>]]></description>
			<content:encoded><![CDATA[If this system lives up to its great reviews; it would be ideal to install and use in our coaches. Filter lasts 6 months (maybe longer in a bus?)and costs &#36;50. Anyone have experience with this product?<br />
<br />
<a href="http://www.nuvoh2o.com/nuvo-systems/nuvo-studio-system.html\" target="_blank">http://www.nuvoh2o.com/nuvo-systems/nuvo...stem.html\</a>]]></content:encoded>
		</item>
		<item>
			<title><![CDATA[Fresh Water System Pumps]]></title>
			<link>http://www.wanderlodgegurus.com/showthread.php?tid=10058</link>
			<pubDate>Sat, 02 Nov 2013 23:11:19 +0000</pubDate>
			<guid isPermaLink="false">http://www.wanderlodgegurus.com/showthread.php?tid=10058</guid>
			<description><![CDATA[Has anyone had any experience in replacing the accumulator tank and old pumps with the new automatic demand pumps?  Shurflo 4008-101-E65 has an internal bypass to do this, but I am reluctant to jump in without knowing how well they perform.  Is there any irritating delay?  Any comments?]]></description>
			<content:encoded><![CDATA[Has anyone had any experience in replacing the accumulator tank and old pumps with the new automatic demand pumps?  Shurflo 4008-101-E65 has an internal bypass to do this, but I am reluctant to jump in without knowing how well they perform.  Is there any irritating delay?  Any comments?]]></content:encoded>
		</item>
		<item>
			<title><![CDATA[Sporlan Valve]]></title>
			<link>http://www.wanderlodgegurus.com/showthread.php?tid=10008</link>
			<pubDate>Wed, 25 Sep 2013 19:15:40 +0000</pubDate>
			<guid isPermaLink="false">http://www.wanderlodgegurus.com/showthread.php?tid=10008</guid>
			<description><![CDATA[My tank fill sporlan valve has been sticking open. It will slowly close when the shore water supply is shut off. It takes it about 5 minutes to do so. <br />
<br />
I have been searching for it now for 3 days with no idea what it looked like. Most owners say that valve is located in the water bay. George Morris said it may also be behind the steel plate covering the water tank on the curb side. <br />
<br />
It is in neither place on my bus. I THINK I finally found it in the second bay above the water pumps jammed behing the expansion tank. I'm not looking forward to cleaning it due to its location.<br /><!-- start: postbit_attachments_attachment -->
<br /><img src="images/attachtypes/image.gif" border="0" alt=".jpg" />&nbsp;&nbsp;<a href="attachment.php?aid=905" target="_blank">Sporlan.JPG</a> (Size: 23.57 KB / Downloads: 1155)
<!-- end: postbit_attachments_attachment -->]]></description>
			<content:encoded><![CDATA[My tank fill sporlan valve has been sticking open. It will slowly close when the shore water supply is shut off. It takes it about 5 minutes to do so. <br />
<br />
I have been searching for it now for 3 days with no idea what it looked like. Most owners say that valve is located in the water bay. George Morris said it may also be behind the steel plate covering the water tank on the curb side. <br />
<br />
It is in neither place on my bus. I THINK I finally found it in the second bay above the water pumps jammed behing the expansion tank. I'm not looking forward to cleaning it due to its location.<br /><!-- start: postbit_attachments_attachment -->
<br /><img src="images/attachtypes/image.gif" border="0" alt=".jpg" />&nbsp;&nbsp;<a href="attachment.php?aid=905" target="_blank">Sporlan.JPG</a> (Size: 23.57 KB / Downloads: 1155)
<!-- end: postbit_attachments_attachment -->]]></content:encoded>
		</item>
		<item>
			<title><![CDATA[Out with old Thomas air pump]]></title>
			<link>http://www.wanderlodgegurus.com/showthread.php?tid=9956</link>
			<pubDate>Mon, 19 Aug 2013 22:15:03 +0000</pubDate>
			<guid isPermaLink="false">http://www.wanderlodgegurus.com/showthread.php?tid=9956</guid>
			<description><![CDATA[For the air toilet, those Thomas pumps don't last, expensive to rebuild, etc. Well, my coachs' previous owner, Paul Lazar, removed that old Thomas and installed a separate air compressor and tank. Works like a champ. He also was in the process of running another air line to the aux compressor for the suspension. Love the coach. She will get a flooring makeover, if I can find someone to do that.]]></description>
			<content:encoded><![CDATA[For the air toilet, those Thomas pumps don't last, expensive to rebuild, etc. Well, my coachs' previous owner, Paul Lazar, removed that old Thomas and installed a separate air compressor and tank. Works like a champ. He also was in the process of running another air line to the aux compressor for the suspension. Love the coach. She will get a flooring makeover, if I can find someone to do that.]]></content:encoded>
		</item>
		<item>
			<title><![CDATA["TankEyes "  on 450 LXi]]></title>
			<link>http://www.wanderlodgegurus.com/showthread.php?tid=9927</link>
			<pubDate>Tue, 06 Aug 2013 12:02:47 +0000</pubDate>
			<guid isPermaLink="false">http://www.wanderlodgegurus.com/showthread.php?tid=9927</guid>
			<description><![CDATA[Good Morning,<br />
Anyone know of the manufacturer that supplied "TankEyes" which was used in the 450s' as the tank level indicators.<br />
<br />
Thank you,<br />
Ross]]></description>
			<content:encoded><![CDATA[Good Morning,<br />
Anyone know of the manufacturer that supplied "TankEyes" which was used in the 450s' as the tank level indicators.<br />
<br />
Thank you,<br />
Ross]]></content:encoded>
		</item>
		<item>
			<title><![CDATA[Sewer Dump Valve]]></title>
			<link>http://www.wanderlodgegurus.com/showthread.php?tid=9913</link>
			<pubDate>Wed, 24 Jul 2013 02:19:33 +0000</pubDate>
			<guid isPermaLink="false">http://www.wanderlodgegurus.com/showthread.php?tid=9913</guid>
			<description><![CDATA[<!-- start: postbit_attachments_attachment -->
<br /><img src="images/attachtypes/image.gif" border="0" alt=".jpg" />&nbsp;&nbsp;<a href="attachment.php?aid=699" target="_blank">Ryobi Tek4 Camera.jpg</a> (Size: 10.59 KB / Downloads: 1803)
<!-- end: postbit_attachments_attachment -->Here's a tip for making a disgusting &amp; hard job easier. <br />
<br />
My black dump valve was not closing all the way as evidenced by the air cylinder handle stoping about 2"s from the complete closed position.  I knew I was in for a quick removal of the sewer cap and quick attachment of the sewer hose. The "stuff" came pouring out as if the valve was completely open. <br />
<br />
After a lot of fresh water flushing; I removed the cylinder and paddle assembly from the valve body. To my surprise, the seal was missing from the paddle!  No wonder that the "stuff" came gushing out like a fire hose...<br />
<br />
Now you can not see into the valve body due to its location. It lays horizonal and way back in the bay. Actually, the space is so small the paddle has to be separated from the cylinder rod to completely remove it from the valve body. You can feel around with a long stick or screwdriver trying to locate the seal or you can go to Home Depot and rent a Ryobi Tek4 inspection camera. I opted for the latter. <br />
<br />
I inserted the camera into the valve body and saw the seal laying on the bottom of the valve. Leaving the camera in the valve body, I made a hook on the end of a wire coat hanger and fished it through the end of the sewer pipe where the hose connects. The camera allowed me to guide the hooked end behind the seal and drag it through the pipe to exit at the hose connection. That camera saved me a whole lot of time and frustration....<br />
<br />
I think I'm going to buy one as there are so many places on a Wanderlodge that are difficult to see when you need to do so.<br />
They are only &#36;99.]]></description>
			<content:encoded><![CDATA[<!-- start: postbit_attachments_attachment -->
<br /><img src="images/attachtypes/image.gif" border="0" alt=".jpg" />&nbsp;&nbsp;<a href="attachment.php?aid=699" target="_blank">Ryobi Tek4 Camera.jpg</a> (Size: 10.59 KB / Downloads: 1803)
<!-- end: postbit_attachments_attachment -->Here's a tip for making a disgusting &amp; hard job easier. <br />
<br />
My black dump valve was not closing all the way as evidenced by the air cylinder handle stoping about 2"s from the complete closed position.  I knew I was in for a quick removal of the sewer cap and quick attachment of the sewer hose. The "stuff" came pouring out as if the valve was completely open. <br />
<br />
After a lot of fresh water flushing; I removed the cylinder and paddle assembly from the valve body. To my surprise, the seal was missing from the paddle!  No wonder that the "stuff" came gushing out like a fire hose...<br />
<br />
Now you can not see into the valve body due to its location. It lays horizonal and way back in the bay. Actually, the space is so small the paddle has to be separated from the cylinder rod to completely remove it from the valve body. You can feel around with a long stick or screwdriver trying to locate the seal or you can go to Home Depot and rent a Ryobi Tek4 inspection camera. I opted for the latter. <br />
<br />
I inserted the camera into the valve body and saw the seal laying on the bottom of the valve. Leaving the camera in the valve body, I made a hook on the end of a wire coat hanger and fished it through the end of the sewer pipe where the hose connects. The camera allowed me to guide the hooked end behind the seal and drag it through the pipe to exit at the hose connection. That camera saved me a whole lot of time and frustration....<br />
<br />
I think I'm going to buy one as there are so many places on a Wanderlodge that are difficult to see when you need to do so.<br />
They are only &#36;99.]]></content:encoded>
		</item>
		<item>
			<title><![CDATA[Just received my new water heater today....]]></title>
			<link>http://www.wanderlodgegurus.com/showthread.php?tid=9849</link>
			<pubDate>Thu, 06 Jun 2013 23:42:09 +0000</pubDate>
			<guid isPermaLink="false">http://www.wanderlodgegurus.com/showthread.php?tid=9849</guid>
			<description><![CDATA[The Atwood marine in my water bay looks a little dated (rust and wet spots tend to look that way to me). I'd guess it is original to my 1991 coach, so it is due for an update, 'tho it still works. <img src="images/smilies/wink.gif" style="vertical-align: middle;" border="0" alt="Wink" title="Wink" /><br />
<br />
So I shopped around and compared features like tank material, location of motor-aided heat ports, wattage requirements for immersion heat.<br />
<br />
And in a late-night decision, against a lot of advice about the dubious value of stainless steel, I ordered an Isotemp Basic 30.  I think it is made in Italy (older Isotemp equipment used in Europe was Italian-made), a very sheik cask-shaped stainless casing with stainless tank inside. It stands in free air, oriented horizontally in the longest dimension, supported by feet.  That's a good design, no moisture will be trapped under it.<br />
<br />
I think this is going to be a project, working around the existing Primus heat exchanger, expansion tank, and pump. I expect to move some things around, as this water heater is significantly wider (but less deep) than the old Atwood.  Today I'll begin removing the old equipment, followed by inspection of the carpet and water bay structure, followed by sealing and rust-proofing.  Actual bay rust will not be a big thing, as the Wanderlodge bays are built of galvanized steel <img src="images/smilies/biggrin.gif" style="vertical-align: middle;" border="0" alt="Big Grin" title="Big Grin" />]]></description>
			<content:encoded><![CDATA[The Atwood marine in my water bay looks a little dated (rust and wet spots tend to look that way to me). I'd guess it is original to my 1991 coach, so it is due for an update, 'tho it still works. <img src="images/smilies/wink.gif" style="vertical-align: middle;" border="0" alt="Wink" title="Wink" /><br />
<br />
So I shopped around and compared features like tank material, location of motor-aided heat ports, wattage requirements for immersion heat.<br />
<br />
And in a late-night decision, against a lot of advice about the dubious value of stainless steel, I ordered an Isotemp Basic 30.  I think it is made in Italy (older Isotemp equipment used in Europe was Italian-made), a very sheik cask-shaped stainless casing with stainless tank inside. It stands in free air, oriented horizontally in the longest dimension, supported by feet.  That's a good design, no moisture will be trapped under it.<br />
<br />
I think this is going to be a project, working around the existing Primus heat exchanger, expansion tank, and pump. I expect to move some things around, as this water heater is significantly wider (but less deep) than the old Atwood.  Today I'll begin removing the old equipment, followed by inspection of the carpet and water bay structure, followed by sealing and rust-proofing.  Actual bay rust will not be a big thing, as the Wanderlodge bays are built of galvanized steel <img src="images/smilies/biggrin.gif" style="vertical-align: middle;" border="0" alt="Big Grin" title="Big Grin" />]]></content:encoded>
		</item>
		<item>
			<title><![CDATA[Shurflow 2088 pump head replacements]]></title>
			<link>http://www.wanderlodgegurus.com/showthread.php?tid=9758</link>
			<pubDate>Tue, 30 Apr 2013 16:11:30 +0000</pubDate>
			<guid isPermaLink="false">http://www.wanderlodgegurus.com/showthread.php?tid=9758</guid>
			<description><![CDATA[FWIW, Shurflow 2088-554-144 fresh water pump head replacements:<br />
<a href="http://www.amazon.com/SHURflo-94-236-08-Replacement-Pump-Head/dp/B00074QUC6/ref=pd_rhf_se_p_t_1_VX4A" target="_blank">http://www.amazon.com/SHURflo-94-236-08-...p_t_1_VX4A</a><br />
<br />
 Part number 94-236-08 is a good number confirmed by Shurflow tech support. 800-942-1153, option #2.]]></description>
			<content:encoded><![CDATA[FWIW, Shurflow 2088-554-144 fresh water pump head replacements:<br />
<a href="http://www.amazon.com/SHURflo-94-236-08-Replacement-Pump-Head/dp/B00074QUC6/ref=pd_rhf_se_p_t_1_VX4A" target="_blank">http://www.amazon.com/SHURflo-94-236-08-...p_t_1_VX4A</a><br />
<br />
 Part number 94-236-08 is a good number confirmed by Shurflow tech support. 800-942-1153, option #2.]]></content:encoded>
		</item>
		<item>
			<title><![CDATA[microphor adjustments]]></title>
			<link>http://www.wanderlodgegurus.com/showthread.php?tid=167</link>
			<pubDate>Tue, 12 Mar 2013 23:54:01 +0000</pubDate>
			<guid isPermaLink="false">http://www.wanderlodgegurus.com/showthread.php?tid=167</guid>
			<description><![CDATA[Hello everyone i am in the process of rebuilding my microphor lf210 does anyone know the proper way of adjusting the water level and the flapper<br />
thanks]]></description>
			<content:encoded><![CDATA[Hello everyone i am in the process of rebuilding my microphor lf210 does anyone know the proper way of adjusting the water level and the flapper<br />
thanks]]></content:encoded>
		</item>
	</channel>