Chuck Wheeler

Does any one have a wiring diagram/
schematic of the monitor panel? When we had our accident a while back the
wiring was damaged at the grey water tank. I thought I could figure it
out but get strange results. Fresh water will indicate correctly if the
grey and black are empty. As the grey tank fills up the black and fresh
water follow it. They all indicate the same. The black also creates
some strange problems as it fills up. Propane is OK. I have looked
through the “files” section of the various BB sites and cannot find
any documentation on the monitor panels.

-
Chuck Wheeler-

1982 FC 31Sb Fort Worth TX

Wayne Kotila

Did you ever get your problem resolved? It sounds like some crossed wiring.
Wayne Kotila
96PT42



From: Chuck Wheeler
To: WanderlodgeForum@yahoogroups.com
Sent: Sat, March 26, 2011 12:31:08 PM
Subject: [WanderlodgeForum] Monitor Panel




Does any one have a wiring diagram/ schematic of the monitor panel? When we had our accident a while back the wiring was damaged at the grey water tank. I thought I could figure it out but get strange results. Fresh water will indicate correctly if the grey and black are empty. As the grey tank fills up the black and fresh water follow it. They all indicate the same. The black also creates some strange problems as it fills up. Propane is OK. I have looked through the “files” section of the various BB sites and cannot find any documentation on the monitor panels.

- Chuck Wheeler-

1982 FC 31Sb Fort Worth TX

Chuck Wheeler

Wayne,

I have a good idea of what it is. I can
measure a ground on the common for the grey tank. The commons are switched to
select the tank you want to measure and all the sensor probes are connected in
parallel so the monitor is always measuring the grey tank plus any other tank
selected. The resulting measurement is the greater of the level in the grey
tank or the selected tank. I started out believing that the sensors were
switched. After helping a buddy with his SOB and looking at a drawing that
Donald Watson found it was pretty obvious once you understood that the commons
were switched and not the sensor probes. I am still going to make a drawing
and schenmatic and will post when done.

- Chuck
Wheeler-



From: WanderlodgeForum@yahoogroups.com [mailto:WanderlodgeForum@yahoogroups.com] On Behalf Of Wayne Kotila

Sent: Wednesday, March 30, 2011
9:52 AM

To: WanderlodgeForum@yahoogroups.com

Subject: Re: [WanderlodgeForum]
Monitor Panel

Did you ever get your problem resolved? It sounds like some
crossed wiring.

Wayne Kotila

96PT42



From: Chuck Wheeler
<cwheeler@...>

To: WanderlodgeForum@yahoogroups.com

Sent: Sat, March 26, 2011 12:31:08
PM

Subject: [WanderlodgeForum]
Monitor Panel



Does any one have a wiring diagram/ schematic of the monitor
panel? When we had our accident a while back the wiring was damaged at
the grey water tank. I thought I could figure it out but get strange
results. Fresh water will indicate correctly if the grey and black are
empty. As the grey tank fills up the black and fresh water follow
it. They all indicate the same. The black also creates some strange
problems as it fills up. Propane is OK. I have looked through the
“files” section of the various BB sites and cannot find any documentation on
the monitor panels.

-
Chuck
Wheeler-

1982 FC 31Sb Fort Worth
TX

Wayne Kotila

Chuck, It sounds like your getting the problem figured out.
Good Luck
Wayne kotila



From: Chuck Wheeler
To: WanderlodgeForum@yahoogroups.com
Sent: Wed, March 30, 2011 10:23:11 AM
Subject: RE: [WanderlodgeForum] Monitor Panel




Wayne,

I have a good idea of what it is. I can measure a ground on the common for the grey tank. The commons are switched to select the tank you want to measure and all the sensor probes are connected in parallel so the monitor is always measuring the grey tank plus any other tank selected. The resulting measurement is the greater of the level in the grey tank or the selected tank. I started out believing that the sensors were switched. After helping a buddy with his SOB and looking at a drawing that Donald Watson found it was pretty obvious once you understood that the commons were switched and not the sensor probes. I am still going to make a drawing and schenmatic and will post when done.

- Chuck Wheeler-



From: WanderlodgeForum@yahoogroups.com [mailto: WanderlodgeForum@yahoogroups.com ] On Behalf Of Wayne Kotila
Sent: Wednesday, March 30, 2011 9:52 AM
To: WanderlodgeForum@yahoogroups.com
Subject: Re: [WanderlodgeForum] Monitor Panel

Did you ever get your problem resolved? It sounds like some crossed wiring.

Wayne Kotila

96PT42



From: Chuck Wheeler < cwheeler@... >
To: WanderlodgeForum@yahoogroups.com
Sent: Sat, March 26, 2011 12:31:08 PM
Subject: [WanderlodgeForum] Monitor Panel

Does any one have a wiring diagram/ schematic of the monitor panel? When we had our accident a while back the wiring was damaged at the grey water tank. I thought I could figure it out but get strange results. Fresh water will indicate correctly if the grey and black are empty. As the grey tank fills up the black and fresh water follow it. They all indicate the same. The black also creates some strange problems as it fills up. Propane is OK. I have looked through the “files” section of the various BB sites and cannot find any documentation on the monitor panels.