I blew the fuse on the generator a few days ago and replaced it. I've
checked the battery, ground, power at the solonoid.
I get NOTHING when I hit the generator start switch.
Any more ideas?
Regards,
GPSGary
84FC35
New fuse is fine.
I've even jumped a car battery directly to the heavy post on the
solenoid just in case it was poor contacts and get nothing.
Regards,
GPSGary
--- In
WanderlodgeForum@yahoogroups.com, "Rob Robinson"
wrote:
>
> You blew a fuse and replaced it. Did the new fuse blow? Check the
new fuse
> for continuity. If the fuse is good then hopefully Chuck Wheeler or
someone
> of his electrical calibar will chime in here.
>
>
> 2008/10/4 hippieforever3
>
> > I blew the fuse on the generator a few days ago and replaced
it. I've
> > checked the battery, ground, power at the solonoid.
> >
> > I get NOTHING when I hit the generator start switch.
> >
> > Any more ideas?
> >
> > Regards,
> > GPSGary
> > 84FC35
> >
> >
> >
>
>
>
> --
> Rob, Sue & Merlin Robinson
> 94 WLWB
>
Flakey fuse cap. Inserted small ball of aluminum foil.
Fixed
Regards,
GPSGary