orbitalsolutions

Walked up to the bus this morning and there was water under it. Went
inside to find the tolite bowl full and slowly overflowing. The bowl
continues to fill even when the city water is off. Both black and grey
tanks are empty.

Does anyone have any idea what is happening?

HELP !!

James
78FC33SB
LasVegas NV

guysmalley

--- In WanderlodgeForum@yahoogroups.com, "orbitalsolutions"

wrote:
>
> Walked up to the bus this morning and there was water under it. Went
> inside to find the tolite bowl full and slowly overflowing. The bowl
> continues to fill even when the city water is off. Both black and grey
> tanks are empty.
>
> Does anyone have any idea what is happening?
>
James,
if it is a step fill bowl maybe the value is stuck, does your bowl have two
pedals?
as far as the water still running maybe the you have rv water pump on, also I
never leave
water on either city or house while I am not there for that reason. if its a
value it is can be
replace I just did mine a month ago

guy smalley
86 pt 4o

orbitalsolutions

Ernie, my head has only one pedal. It is a Thetford Aqua-Magic V
model. Thanks for the reply. I'm trying to figure it out, and
thought I might find some help on this forum.


James
78FC33SB
LasVegas NV


--- In WanderlodgeForum@yahoogroups.com, "guysmalley"
wrote:
>
> --- In WanderlodgeForum@yahoogroups.com, "orbitalsolutions"

> wrote:
> >
> > Walked up to the bus this morning and there was water under it.
Went
> > inside to find the tolite bowl full and slowly overflowing. The
bowl
> > continues to fill even when the city water is off. Both black
and grey
> > tanks are empty.
> >
> > Does anyone have any idea what is happening?
> >
> James,
> if it is a step fill bowl maybe the value is stuck, does your bowl
have two pedals?
> as far as the water still running maybe the you have rv water pump
on, also I never leave
> water on either city or house while I am not there for that
reason. if its a value it is can be
> replace I just did mine a month ago
>
> guy smalley
> 86 pt 4o
>

Ralph L. Fullenwider

James:

As mentioned check the fill valve attached to the foot pedal. Also check
the vacuum breaker at the rear of the commode inside the pedestal up high
near the top. But it really sounds like the fill valve. Easy replacement.

Ralph and Charolette Fullenwider
Ralph's RV Solutions, Duncan, Oklahoma
http://home.swbell.net/rlf47/index.htm

At 03:25 PM 4/22/2006 +0000, you wrote:
>Ernie, my head has only one pedal. It is a Thetford Aqua-Magic V
>model. Thanks for the reply. I'm trying to figure it out, and
>thought I might find some help on this forum.
>
>
>James
>78FC33SB
>LasVegas NV
>
>

Blair

I won't touch this one, but someone else will.
Blair in Oregon




At 08:25 AM 4/22/2006, you wrote:
>Ernie, my head has only one pedal.
>James

orbitalsolutions

Thanks Ralph. What ever was causing that valve to open is no longer
there. It seems to operate just fine. I guess a solid particle
must of fouled it and has now fulshed it's self clean. The bowl is
no longer filling.

Oh well, alls well that ends well. Thanks.


James
78FC33SB
LasVegas NV


--- In WanderlodgeForum@yahoogroups.com, "Ralph L. Fullenwider"
wrote:
>
> James:
>
> As mentioned check the fill valve attached to the foot pedal. Also
check
> the vacuum breaker at the rear of the commode inside the pedestal
up high
> near the top. But it really sounds like the fill valve. Easy
replacement.
>
> Ralph and Charolette Fullenwider
> Ralph's RV Solutions, Duncan, Oklahoma
> http://home.swbell.net/rlf47/index.htm
>
> At 03:25 PM 4/22/2006 +0000, you wrote:
> >Ernie, my head has only one pedal. It is a Thetford Aqua-Magic V
> >model. Thanks for the reply. I'm trying to figure it out, and
> >thought I might find some help on this forum.
> >
> >
> >James
> >78FC33SB
> >LasVegas NV
> >
> >
>

Stephen Birtles

Sounds like you should rebuild the inlet valve
Go to manufactureres website they all have parts breakdown and parts
number for service parts
Stephen 77fc35


--- In WanderlodgeForum@yahoogroups.com, "orbitalsolutions"
wrote:
>
> Walked up to the bus this morning and there was water under it. Went
> inside to find the tolite bowl full and slowly overflowing. The bowl
> continues to fill even when the city water is off. Both black and grey
> tanks are empty.
>
> Does anyone have any idea what is happening?
>
> HELP !!
>
> James
> 78FC33SB
> LasVegas NV
>
Reference URL's